DescriptionHigh Efficiency:
•Conversion efficiency is 97.8%?European conversion efficiency is 97.4%;the Total Harmonic Distortion(THD) is less than 1%; The MPPT Adaptation Efficiency is over 99.5%
Ingenious Design:
•Unique design, 30% smaller and lighter in size and weight; Patented integrated fanless and natural convection cooling, lower noise; Professional ID design, good appearance,good durability
High Safety and Reliability:
•Complete protective functions(over-voltage protection, short-circuit protection, anti-islanding protection,thermal protection, over load protection);Pass stringent tests(MTBF test, HALT test, Salt Spray test, Hi-pot test, Full-function test based on ATS platform; Burn-in time over 12 hours); DC switch disconnector; Comply with the latest VDE-AR-N4105 standard requirements; standard configuration for GFCI
DC Input Data
Max.PV-generator power[w]
5400
Max.Dc power each MPPT[w]
3000
Max.Dc voltage[v]
580
MPPT voltage range[v]
125~550
Turn on DC voltage[v]
125
Max.DC work current[A]
2*15
Number of MPP trackers
2(can parrallel)
DC-connection
MC IV or HC IV connector
Self-consumption[w]
5
AC Output Data
Nominal AC power[w]
4600
Max.AC power[w]
5100
Max.output current[A]
25
Nominal output voltage range
According to VDE0126-1-1, RD1663, ENEL, GB,SAA
AC grid frequency
According to VDE0126-1-1, RD1663, ENEL, GB,SAA
THD(AC output current)
?2%
Power factor
0.95leading...0.95lagging
AC connector
Single phase with clamps
Efficiency
Max.efficiency
97.8%
Euro efficiency
>97.4%
MPPT adaptation efficiency
>99.5%
Safty Equipment
Leakage current monitoring
Integrated
DC disconnector switch
Optional
Islanding protection
AFD
Grid monitoring
According to VDE 0126-1-1/A1,AS4777.1/2/3, RD1663,
ENEL Guide,G83,G95-2
Normative Reference
EMC-compliant according to
EN 61000-6-1,EN 61000-6-2, EN 61000-6-3,EN 61000-6-4
Safety compliance
According to IEC62109-1,AS3100
General Data
Dimensions(W*H*D) [mm]
390*417*165
Net weight [kg]
20
Housing
For outdoor and indoor
Mounting information
Wall bracket
Operating temperature range
-20??60??up 45? derating?
Relative humidity
0 ~ 95%
Site altitude[m]
2000
IP proection type
IP65
Topology
Transformerless
Cooling concept
Nature Convection
Noise level[dB]
?25
Display
3LED;3.5" LCD
Communication
USB2.0;485?wireless?bluetooth optional?
Standard warranty[years]
5/10(optional?
High Efficiency:
•Conversion efficiency is 97.8%?European conversion efficiency is 97.4%;the Total Harmonic Distortion(THD) is less than 1%; The MPPT Adaptation Efficiency is over 99.5%
Ingenious Design:
•Unique design, 30% smaller and lighter in size and weight; Patented integrated fanless and natural convection cooling, lower noise; Professional ID design, good appearance,good durability
High Safety and Reliability:
•Complete protective functions(over-voltage protection, short-circuit protection, anti-islanding protection,thermal protection, over load protection);Pass stringent tests(MTBF test, HALT test, Salt Spray test, Hi-pot test, Full-function test based on ATS platform; Burn-in time over 12 hours); DC switch disconnector; Comply with the latest VDE-AR-N4105 standard requirements; standard configuration for GFCI
DC Input Data | Max.PV-generator power[w] | 5400 |
Max.Dc power each MPPT[w] | 3000 | |
Max.Dc voltage[v] | 580 | |
MPPT voltage range[v] | 125~550 | |
Turn on DC voltage[v] | 125 | |
Max.DC work current[A] |
2*15 | |
Number of MPP trackers | 2(can parrallel) | |
DC-connection | MC IV or HC IV connector | |
Self-consumption[w] | 5 | |
AC Output Data | Nominal AC power[w] | 4600 |
Max.AC power[w] | 5100 | |
Max.output current[A] | 25 | |
Nominal output voltage range | According to VDE0126-1-1, RD1663, ENEL, GB,SAA | |
AC grid frequency | According to VDE0126-1-1, RD1663, ENEL, GB,SAA | |
THD(AC output current) | ?2% | |
Power factor | 0.95leading...0.95lagging | |
AC connector | Single phase with clamps | |
Efficiency | Max.efficiency | 97.8% |
Euro efficiency | >97.4% | |
MPPT adaptation efficiency | >99.5% | |
Safty Equipment | Leakage current monitoring | Integrated |
DC disconnector switch | Optional | |
Islanding protection | AFD | |
Grid monitoring |
According to VDE 0126-1-1/A1,AS4777.1/2/3, RD1663,
ENEL Guide,G83,G95-2
|
|
Normative Reference | EMC-compliant according to | EN 61000-6-1,EN 61000-6-2, EN 61000-6-3,EN 61000-6-4 |
Safety compliance | According to IEC62109-1,AS3100 | |
General Data | Dimensions(W*H*D) [mm] | 390*417*165 |
Net weight [kg] | 20 | |
Housing | For outdoor and indoor | |
Mounting information | Wall bracket | |
Operating temperature range | -20??60??up 45? derating? | |
Relative humidity | 0 ~ 95% | |
Site altitude[m] | 2000 | |
IP proection type | IP65 | |
Topology | Transformerless | |
Cooling concept | Nature Convection | |
Noise level[dB] | ?25 | |
Display | 3LED;3.5" LCD | |
Communication | USB2.0;485?wireless?bluetooth optional? | |
Standard warranty[years] | 5/10(optional? |